General

Milan AVB Routing of Normal Mode GALAXY when in the same AVB Group as Spacemap Mode GALAXY

When a Galileo GALAXY is in Spacemap Mode, the AVB controller embedded in the GALAXY processor controls the AVB input assignments of all the GALAXY processors that have the same AVB Group Name on the same network. This includes any GALAXY processors operating in Normal mode. All AVB connections established when a GALAXY processor is in Normal mode will be overwritten when it is re-started in Spacemap Mode and the Spacemap Go System is configured with the Spacemap Go app.

To manually control the AVB input connections of a GALAXY processor using the Compass software or other AVB controller software, change the AVB Group Name of the GALAXY processor to one that does not include any GALAXY processors in Spacemap Mode.